An EICR, Electrical Installation Condition Report, is a formal assessment of the safety and compliance of the fixed electrical installation in a property. A qualified electrician inspects, tests and records the condition of the wiring, circuits, consumer unit, earthing and bonding arrangements, then assigns observation codes to any issues found.
Bains Electrical provides EICR testing for landlords, homeowners and commercial property owners, and we issue full reports on the day of inspection wherever the scope allows.
As holders of the 2026 Global Recognition Award for safety, compliance and quality electrical work, our team carries out every EICR inspection with the thoroughness and accuracy the certificate demands.
We offer transparent EICR pricing, a free estimate for commercial inspections, and prompt report turnaround so you have the documentation you need without delay.
Ready to get in touch?
If you’re looking for a Glasgow based electricians that combines traditional Scottish values of honesty and hard work with modern electrical expertise, then get in touch!
EICR Electricians
EICR Price Per Circuit
What the certificate tells you. The electrician produces an EICR certificate at the end of an electrical installation condition report inspection, recording the findings of the assessment and confirming whether the installation is satisfactory or unsatisfactory. A satisfactory EICR normally means the inspector found no C1, C2 or FI observations affecting the outcome. An unsatisfactory result means the inspection identified one or more issues requiring remediation.
Observation codes explained. The certificate documents every observation code the inspector assigns during the inspection, including C1 for danger present, C2 for potentially dangerous, C3 for improvement recommended and FI for further investigation required. It also specifies the recommended next inspection date, which should reflect the property type, use, condition and inspection findings rather than a fixed period for every domestic property. Bains Electrical provides detailed, clearly written EICR certificates that are easy to understand, with a full explanation of any observations and, where remedial work is required, a separate quotation.
EICR Landlord
Landlord EICR Cost
Private landlords have a legal obligation under the Repairing Standard to ensure that electrical installations, fixtures and relevant landlord-provided electrical equipment are kept in a reasonable state of repair and proper working order.
- Landlords must arrange an electrical safety inspection before a property is first let and then at intervals of no more than five years
- The most recent EICR must be kept for records and provided to tenants as required before or during the tenancy. Landlords managing furnished rentals often arrange PAT testing for their appliances at the same visit.
- HMO properties may have additional licensing conditions, so landlords should check the relevant licence requirements
Bains Electrical carries out landlord EICR inspections near you efficiently and professionally, working around tenants where possible to minimise disruption. We provide full documentation for compliance records and can carry out any remedial work identified during the inspection.
EICR Certificate Cost
EICR and PAT Test
EICR cost depends on the size of the property, the number of circuits, and whether it is a domestic or commercial inspection.
- Domestic EICR cost for a two or three-bedroom property is typically within a clearly defined range and can be confirmed at booking
- Larger homes, commercial properties and HMO properties take longer to inspect due to the higher number of circuits and greater scope of the schedule of inspections required
- Bains Electrical offers competitive EICR pricing with no hidden charges and provides a clear price at booking so you know exactly what to expect
Bains Electrical confirms the cost at booking where possible and provides a free estimate for larger or commercial EICR inspections before work begins.
EICR Testing
Electrical Safety Certificates
The visual assessment. A thorough EICR inspection covers every aspect of the fixed electrical installation in a property, from the main incoming supply through to the furthest socket outlet and light fitting. The inspection process begins with a detailed visual assessment of the consumer unit, checking for signs of overheating, incorrect wiring, missing protective devices and inadequate labelling.
Electrical testing. Our qualified electricians then carry out a series of electrical tests on each circuit in turn, including insulation resistance testing, earth fault loop impedance testing, RCD testing, polarity testing and continuity testing. These tests confirm that each circuit is correctly wired, properly protected and capable of safely handling its rated load.
The completed report. We record all test results in a schedule of test results and a schedule of inspections, which form part of the completed EICR report. Any observations are coded as C1, C2, C3 or FI (further investigation required) and accompanied by a clear description of the issue and the action required. We provide the completed report to you on the day of the inspection. Bains Electrical carries out EICR inspection and testing in line with BS 7671 requirements and relevant inspection-and-testing guidance, including IET Guidance Note 3 where applicable.
Electrician EICR
Domestic Electrical Safety Certificate
EICR cost depends on the size of the property, the number of circuits, and whether it is a domestic or commercial inspection.
- Domestic EICR cost for a two or three-bedroom property is typically within a clearly defined range and can be confirmed at booking
- Larger homes, commercial properties and HMO properties take longer to inspect due to the higher number of circuits and greater scope of the schedule of inspections required
- Bains Electrical offers competitive EICR pricing with no hidden charges and provides a clear price at booking so you know exactly what to expect
Bains Electrical confirms the cost at booking where possible and provides a free estimate for larger or commercial EICR inspections before work begins.
EICR Report
Commercial Electrical Safety Certificate
The EICR report is a detailed document that records the agreed scope of the electrical inspection and provides a clear picture of the installation’s condition at the time of testing.
- The report includes a schedule of inspections, a schedule of test results and a summary of any observations noted during the assessment
- The inspector assigns each observation a code: C1 for danger present, C2 for potentially dangerous, C3 for improvement recommended or FI for further investigation required
- The report confirms whether the overall result is satisfactory or unsatisfactory and specifies the recommended date for the next periodic inspection
Our EICR reports are clear, accurate and professionally presented. We provide a copy to the property owner on the day of completion and can supply additional copies for letting agents, mortgage providers or insurers on request.
Landlord EICR Certificate
EICR Services
C1, C2 and FI observations. When an EICR identifies C1, C2 or FI observations, the installation will usually need remedial work or further investigation before it can be treated as satisfactory. C1 means danger is present and the electrician should make the installation safe immediately where practical. C2 means potentially dangerous and needs urgent remedial action, while FI means further investigation is required without delay. Bains Electrical explains each observation clearly and provides a separate free estimate for any remedial work needed.
C3 observations and remedial certification. A C3 observation means improvement recommended and does not normally make the EICR unsatisfactory on its own. Bains Electrical can price C3 improvements separately, alongside any urgent C1, C2 or FI work. Once remedial work is complete, we test the affected circuits and issue the appropriate remedial-work certification, such as a Minor Electrical Installation Works Certificate or Electrical Installation Certificate. This gives you clear evidence that the identified work has been completed.
Commercial EICR
EICR Electrical Testing
Commercial properties have their own EICR requirements, with inspection frequency and scope determined by the type of premises and the way it is used.
- Commercial EICR inspections typically require more circuits to be tested and a more detailed schedule of inspections than an equivalent domestic property
- The recommended maximum interval between commercial EICR inspections is five years for most premises, though higher-risk environments may require more frequent inspection
- Bains Electrical carries out commercial EICR inspections for offices, retail premises, workshops and other business properties
Our commercial EICR service provides the detailed, accurate report that business owners and property managers need to demonstrate compliance with current electrical safety obligations. We provide a free estimate for commercial EICR work before inspection dates are agreed.
Periodic Electrical Inspection
EICR Specialists
Understanding how often an EICR is required helps property owners and landlords stay ahead of their compliance obligations.
- For private rental properties, electrical safety inspection is required before first letting and then at intervals of no more than five years
- For owner-occupied domestic properties, the recommended interval is ten years, though older properties or those with outdated wiring may benefit from more frequent inspection
- For commercial properties, the recommended interval varies by premises type and the risk level of the electrical installation
Bains Electrical can advise on the appropriate inspection frequency for your specific property near you and arrange a booking that fits your schedule.